# Ceph Pool-Full Diagnosis & Recovery — 2026-07-04
|
||||
|
||||
## Symptoms
|
||||
|
||||
After adding CT 137's 20 GB RBD to `media_ec`, **6 pools simultaneously showed 100% full** (`MAX AVAIL = 0 B`) despite the HDD class having 6.3 TB free.
|
||||
|
||||
## Root Cause
|
||||
|
||||
A single OSD (osd.10, 982 GB) reached exactly **95% utilization** = `full_ratio`. Ceph blocks ALL writes to PGs mapped to a full OSD. Since nearly every pool has PGs on osd.10, all pools became unwritable — even though osd.6 (2.8 TB) had 2.5 TB free.
|
||||
|
||||
### Why osd.10 Filled First
|
||||
|
||||
CRUSH distributes data by OSD weight. osd.10 and osd.7 are ~1 TB disks; osd.6 and osd.8 are ~2.8 TB disks. The smaller OSDs filled faster because data grew unevenly. The `VAR` column in `ceph osd df` showed osd.10 at 2.13x average utilization vs osd.6 at 0.20x.
|
||||
|
||||
## Diagnosis Commands
|
||||
|
||||
```bash
|
||||
# Per-OSD utilization (look for %USE > 90% and high VAR)
|
||||
ceph osd df
|
||||
|
||||
# Pool availability (MAX AVAIL = 0 means full)
|
||||
ceph df
|
||||
|
||||
# Cluster health (look for "full osd" and "pool(s) full")
|
||||
ceph -s
|
||||
|
||||
# Check full ratio threshold
|
||||
ceph osd dump | grep full_ratio
|
||||
# Default: full_ratio 0.95, nearfull_ratio 0.93, backfillfull_ratio 0.95
|
||||
```
|
||||
|
||||
## Recovery Procedure
|
||||
|
||||
### Step 1: Raise full_ratio temporarily
|
||||
|
||||
```bash
|
||||
ceph osd set-full-ratio 0.97
|
||||
```
|
||||
|
||||
This unblocks writes immediately. Pools regain `MAX AVAIL > 0`. Safe as a temporary measure while rebalancing.
|
||||
|
||||
### Step 2: Drain overloaded OSDs
|
||||
|
||||
```bash
|
||||
# Automatic: reweight all overloaded OSDs at once
|
||||
ceph osd reweight-by-utilization
|
||||
# Moves PGs away from OSDs above average utilization threshold
|
||||
|
||||
# Manual: target specific OSDs for aggressive draining
|
||||
ceph osd reweight 10 0.5 # drain to 50% of CRUSH weight
|
||||
ceph osd reweight 7 0.8 # moderate drain
|
||||
```
|
||||
|
||||
### Step 3: Speed up backfill (optional, moderate)
|
||||
|
||||
```bash
|
||||
# Allow 2 backfills per OSD (default: 1)
|
||||
ceph config set osd osd_max_backfills 2
|
||||
# Or inject directly:
|
||||
ceph tell osd.<N> injectargs "--osd_max_backfills=2"
|
||||
|
||||
# Reduce recovery sleep (default: 0.1s)
|
||||
ceph config set osd osd_recovery_sleep 0.05
|
||||
```
|
||||
|
||||
**Tradeoffs of increasing backfill speed:**
|
||||
- Higher client I/O latency (VMs feel slower)
|
||||
- More "slow ops" warnings (we already had 4)
|
||||
- Higher CPU/IO load on stressed OSDs
|
||||
- May worsen BlueFS spillover
|
||||
|
||||
**Recommendation:** Only double `osd_max_backfills` (1→2) and halve `recovery_sleep` (0.1→0.05). Don't go aggressive on production clusters.
|
||||
|
||||
### Step 4: Verify recovery
|
||||
|
||||
```bash
|
||||
# Watch recovery progress
|
||||
ceph -s | grep -A2 "io:"
|
||||
# recovery: 32 MiB/s, 8 objects/s
|
||||
|
||||
# Track misplaced objects
|
||||
ceph -s | grep "misplaced"
|
||||
# 353960/1858594 objects misplaced (19%)
|
||||
|
||||
# Estimate time: misplaced_objects / objects_per_second
|
||||
# Or: misplaced_data_bytes / recovery_rate_bytes_per_second
|
||||
```
|
||||
|
||||
### Step 5: Restore full_ratio after rebalance
|
||||
|
||||
```bash
|
||||
# Once OSDs are balanced (< 80% on all), restore default
|
||||
ceph osd set-full-ratio 0.95
|
||||
```
|
||||
|
||||
## Backfill Blocking Issues
|
||||
|
||||
### backfill_toofull
|
||||
|
||||
If a target OSD is too full to accept backfill data, PGs stay in `backfill_toofull` state. Fix: lower the reweight of the full OSD further, or raise `backfillfull_ratio`:
|
||||
|
||||
```bash
|
||||
ceph osd set-backfillfull-ratio 0.97
|
||||
```
|
||||
|
||||
### injectargs not sticking
|
||||
|
||||
`ceph tell osd.N injectargs` may not reliably set all parameters. `osd_recovery_sleep` in particular gets reset to 0. Use `ceph config set osd` for persistent values, and verify with `ceph tell osd.N config get <param>`.
|
||||
|
||||
### CRITICAL: `ceph config set osd osd_max_backfills` does NOT apply at runtime
|
||||
|
||||
Setting `ceph config set osd osd_max_backfills 3` updates the MON config store, but **already-running OSD daemons keep using their old value (1)**. The change only takes effect on next OSD restart. Two ways to apply at runtime:
|
||||
|
||||
**Method A — `ceph tell osd.N injectargs` (runtime, no restart):**
|
||||
```bash
|
||||
# Apply to each HDD OSD individually
|
||||
ceph tell osd.7 injectargs "--osd_max_backfills 3"
|
||||
ceph tell osd.1 injectargs "--osd_max_backfills 3"
|
||||
ceph tell osd.10 injectargs "--osd_max_backfills 3"
|
||||
# For OSDs on other nodes, SSH there first or use ceph tell remotely
|
||||
|
||||
# ⚠️ Output is CONFUSING — prints all related config vars with empty values like:
|
||||
# osd_max_backfills = '' osd_recovery_max_active = '' ...
|
||||
# But the change DID take effect. Verify with:
|
||||
ceph daemon osd.7 config get osd_max_backfills
|
||||
# Should return: {"osd_max_backfills": "3"}
|
||||
```
|
||||
|
||||
**Method B — Restart OSD daemon (pick up MON config):**
|
||||
```bash
|
||||
# ⚠️ MUST restart on the correct node! Use ceph osd find to locate:
|
||||
ceph osd find 7
|
||||
# Returns JSON with "host": "proxmox7" and IP
|
||||
|
||||
# Then SSH to THAT node and restart:
|
||||
ssh proxmox7 "systemctl restart ceph-osd@7"
|
||||
# ❌ WRONG: restarting on a node that doesn't host the OSD →
|
||||
# "OSD data directory /var/lib/ceph/osd/ceph-7 does not exist; bailing out"
|
||||
```
|
||||
|
||||
**Verification — check runtime value on each OSD:**
|
||||
```bash
|
||||
ceph daemon osd.N config get osd_max_backfills
|
||||
# Returns actual runtime value. If still "1", the config hasn't been applied.
|
||||
```
|
||||
|
||||
### `osd_recovery_max_active` cannot be effectively changed
|
||||
|
||||
`ceph config set osd osd_recovery_max_active 3` accepts the value but OSDs report 0 (meaning auto/default). `injectargs` also shows empty. This appears to be a Ceph limitation — the parameter is managed internally. Do not waste time trying to force it.
|
||||
|
||||
### Also raise `nearfull_ratio` alongside `backfillfull_ratio`
|
||||
|
||||
When an OSD is above 93%, it triggers `nearfull` warnings which add additional pool-level flags (`nearfull` on pools). If you only raise `backfillfull_ratio` to 0.97 but leave `nearfull_ratio` at 0.93, pools still show warnings and recovery may be partially blocked. Raise both together:
|
||||
|
||||
```bash
|
||||
ceph osd set-backfillfull-ratio 0.97
|
||||
ceph osd set-nearfull-ratio 0.97
|
||||
# Verify:
|
||||
ceph osd dump | grep -E "nearfull_ratio|backfillfull_ratio"
|
||||
```
|
||||
|
||||
### Recovery speed progression
|
||||
|
||||
After applying all tweaks, recovery speed increases progressively as OSDs pick up new config:
|
||||
|
||||
| Stage | Recovery Speed | Notes |
|
||||
|-------|---------------|-------|
|
||||
| Before intervention | 0 MiB/s (stuck) | backfillfull blocks all backfill |
|
||||
| After ratio increase + reweight | 22-23 MiB/s, 5 obj/s | 1-2 PGs backfilling |
|
||||
| After osd_max_backfills=3 via injectargs | 34 MiB/s, 8 obj/s | Still only 2-3 PGs simultaneous |
|
||||
|
||||
Even with `osd_max_backfills=3`, expect only 2-3 PGs backfilling simultaneously — Ceph schedules conservatively. The throughput improvement comes from larger transfer windows, not more parallel PGs.
|
||||
|
||||
### Recovery monitoring cron pattern
|
||||
|
||||
Set up a recurring check to track progress and get alerted when complete:
|
||||
|
||||
```
|
||||
Schedule: every 30 minutes
|
||||
Command: ssh to monitor node, run `ceph status`, report:
|
||||
- PGs remapped/backfilling count
|
||||
- % misplaced objects
|
||||
- OSD 7 utilization
|
||||
- Recovery speed
|
||||
- Alert if any OSD down or health ERR
|
||||
- Announce "COMPLETE" when 0 remapped PGs
|
||||
```
|
||||
|
||||
## Estimating Backfill Duration
|
||||
|
||||
| Metric | Formula | Example |
|
||||
|--------|---------|---------|
|
||||
| By objects | misplaced_objects ÷ objs/sec | 353,960 ÷ 8 = ~12h |
|
||||
| By bytes | misplaced_bytes ÷ bytes/sec | 418 GB ÷ 32 MiB/s = ~3.6h |
|
||||
| Realistic | Take the higher estimate, factor in PG scheduling | 4-8h |
|
||||
|
||||
Only a few PGs backfill simultaneously (controlled by `osd_max_backfills`). 192 PGs in `backfill_wait` won't all start at once.
|
||||
|
||||
---
|
||||
|
||||
# OSD Preparation on Proxmox Nodes — 2026-07-04
|
||||
|
||||
## Hardware Assessment Pattern
|
||||
|
||||
Before adding HDD OSDs to a node, verify:
|
||||
|
||||
1. **Available SATA/SAS ports:**
|
||||
```bash
|
||||
lspci | grep -i "sas\|sata\|nvme\|raid\|hba"
|
||||
ls /sys/class/ata_port/
|
||||
dmesg | grep -i "ahci\|ata[0-9]"
|
||||
```
|
||||
⚠️ AHCI controllers may show N ports but only implement a subset. Check dmesg for `"ports implemented (port mask 0xN)"`. An OptiPlex 3070 showed 5 SATA ports but only port 0x1 (1 port) was implemented.
|
||||
|
||||
2. **Solution for limited ports:** Install a PCIe HBA card (LSI 9211-8i / 9207-8i in IT mode) to connect additional SATA/SAS drives.
|
||||
|
||||
3. **Existing OSD inventory:**
|
||||
```bash
|
||||
ceph osd tree | grep -A20 "host <hostname>"
|
||||
ceph-volume lvm list
|
||||
```
|
||||
|
||||
## WAL/DB Space Preparation
|
||||
|
||||
### Identifying available flash space
|
||||
|
||||
```bash
|
||||
# LVM VG free space on system disk
|
||||
vgs pve
|
||||
lvs pve
|
||||
|
||||
# Check if thin pool is unused (safe to remove)
|
||||
pvesm list local-lvm # if storage doesn't exist, thin pool is orphaned
|
||||
lvdisplay pve/data # check allocation %
|
||||
```
|
||||
|
||||
### Repurposing unused thin pool for WAL/DB
|
||||
|
||||
If `pve/data` thin pool exists but is 0% allocated and not registered as a PVE storage, it can be removed to free NVMe space:
|
||||
|
||||
```bash
|
||||
# Remove unused thin pool
|
||||
lvremove pve/data
|
||||
lvremove pve/data_tmeta
|
||||
lvremove pve/data_tdata
|
||||
# Or simply: lvremove pve/data (removes associated meta)
|
||||
|
||||
# Now VG has ~141 GB free for WAL/DB volumes
|
||||
# Create DB LVs for new OSDs
|
||||
lvcreate -L 30G -n osd-db-<id> pve
|
||||
```
|
||||
|
||||
### Rule: No loopback files for DB/WAL
|
||||
|
||||
Per user policy: Ceph DB/WAL must use real partitions or LVs, never loopback files. Options:
|
||||
- Repurpose swap partition (if RAM is adequate)
|
||||
- Shrink root LV (risky)
|
||||
- Remove unused thin pools
|
||||
- Add a physical SSD/NVMe
|
||||
|
||||
## Node Checklist for Adding OSDs
|
||||
|
||||
1. ☐ Verify physical SATA/SAS ports available (or install HBA)
|
||||
2. ☐ Verify disks are SMART-clean (`smartctl -a /dev/sdX`)
|
||||
3. ☐ Prepare WAL/DB space on flash (real partition/LV, no loopback)
|
||||
4. ☐ Create DB LVs: `lvcreate -L 30G -n osd-db-N pve`
|
||||
5. ☐ Create OSDs: `ceph-volume lvm create --data /dev/sdX --block.db pve/osd-db-N`
|
||||
6. ☐ Verify OSD joins cluster: `ceph osd tree`
|
||||
7. ☐ Check rebalance: `ceph -s`
|
||||
8. ☐ Set `osd_max_backfills` back to 1 after rebalance completes
|
||||
Reference in New Issue