Xenia Coffee Machine REST API Reference

Device: Xenia Coffee (ESP32-based controller) IP: 10.0.50.128 (VLAN 50/IoT) Firmware: ESP FW 3.9 Serial: 313253795029 Web UI: http://10.0.50.128/ (Bootstrap, German)

API Discovery

The JS bundle reveals all endpoints:

curl -s --compressed http://10.0.50.128/js/index_combined.js | grep -oP '/api/v2/[a-z_]+'

Endpoints

GET /api/v2/overview

Returns live machine telemetry. Poll this for sensor data.

{
  "MA_EXTRACTIONS": 1877,
  "MA_OPERATING_HOURS": 39140,
  "MA_STATUS": 0,              // 0=Off, 1=On
  "MA_CLOCK": 1318439,
  "MA_CUR_PWR": 0,             // Watts (current draw)
  "MA_MAX_PWR": 10,            // Max ampere setting
  "MA_ENERGY_TOTAL_KWH": 13.25,
  "BG_SENS_TEMP_A": 32.7,     // Brew group temp °C
  "BG_LEVEL_PW_CONTROL": 0,
  "PU_SENS_PRESS": 0,         // Pump pressure
  "PU_LEVEL_PW_CONTROL": 0,
  "PU_SET_LEVEL_PW_CONTROL": 0,
  "SB_SENS_PRESS": 0,         // Steam boiler pressure
  "BB_SENS_TEMP_A": 32.2,     // Brew boiler temp °C
  "BB_LEVEL_PW_CONTROL": 0,
  "SB_STATUS": 1,              // Steam boiler status
  "MA_LAST_EXTRACTION_ML": ""
}

GET /api/v2/machine

Machine configuration and identity.

{
  "MA_TYPE": 0,
  "MA_FIX_WATER_SUPPLY": 0,
  "MA_HEATUP_FLUSH_EN": 0,
  "MA_SET_TIMER_ECO_MA": 0,
  "MA_SET_TIMER_POWERDOWN": 0,
  "MA_MAX_AMPERE": 10,
  "MA_ENERGY_TOTAL_KWH": 13.25,
  "FW_VERSION_MAJOR": 0,
  "FW_VERSION_MINOR": 0,
  "ESP_FW_MAJOR": 3,
  "ESP_FW_MINOR": 9,
  "MA_SN": "313253795029"
}

POST /api/v2/machine/control

Power control endpoint. POST with JSON body:

  • {"action": 5} — Turn ON
  • {"action": 3} — Turn OFF
  • {"action": 4} — ECO mode

HA rest_command.xenia_machine_control calls this endpoint.

Other Endpoints

  • GET /api/v2/toggle_sb — Toggle steam boiler
  • GET /api/v2/inc_dec — Increment/decrement parameter
  • GET /api/v2/inc_dec_bb — Adjust brew boiler
  • GET /api/v2/inc_dec_sb — Adjust steam boiler
  • GET /api/v2/language — Language setting
  • GET /api/v2/overview_single — Single-value overview (used for set temperatures)
  • GET /api/v2/system/serial — Serial number
  • GET /api/v2/system/reset_serial — Reset serial
  • GET /get_all_params — All parameters (returns empty in observed session)
  • GET /api/brew_start — Start a brew shot

Web UI Pages

  • / — Overview (dashboard)
  • /machine — Machine settings
  • /brewgroup — Brew group settings
  • /brewboiler — Brew boiler settings
  • /scripts — Script management
  • /paddle — Paddle configuration
  • /pid — PID tuning
  • /steamboiler — Steam boiler settings

HA Integration (confirmed 2026-07-10)

Configuration Architecture

The Xenia integration uses a hybrid approach:

  1. Modern rest: integration (in configuration.yaml) — polls /api/v2/overview and /api/v2/overview_single for raw machine data
  2. Template entities (in configuration.yaml under template:) — derive human-readable sensors from the REST sensor attributes
  3. rest_command: — sends control commands to the machine
  4. Manual device registry entry — groups all entities under one "Xenia" device (see "Device Creation" below)

Working Entities

Entity Type Source
sensor.xenia_machine_data REST sensor /api/v2/overview (modern rest: syntax)
sensor.xenia_set_temperatures REST sensor /api/v2/overview_single (modern rest: syntax)
sensor.xenia_status Template sensor Derived from MA_STATUS (On/Off)
sensor.brew_group_temperature Template sensor BG_SENS_TEMP_A
sensor.brew_boiler_temperature Template sensor BB_SENS_TEMP_A
sensor.brew_group_set_temperature Template sensor Set temp
switch.xenia_power_2 Template switch Calls rest_command.xenia_machine_control
rest_command.xenia_machine_control REST command POST /api/v2/machine/control

Broken/Orphaned Entities

Entity Issue
sensor.xenia_current_power_2 unavailable — derived from broken integration sensor
sensor.xenia_total_energy_2 unavailable — derived from broken integration sensor
switch.xenia_power unavailable, restored: true — old entity, superseded by switch.xenia_power_2

Device Creation (confirmed 2026-07-10)

Challenge: device_info is NOT supported in rest: or template: YAML integrations. HA rejects it with "Invalid config for 'rest': 'device_info' is an invalid option".

Solution: Manually create the device in .storage/core.device_registry and link entities via .storage/core.entity_registry, using SSH access to the HA container (see "HAOS Advanced SSH Addon Access" in SKILL.md).

Result: Device "Xenia" (ID: 42aef3df-3746-41bd-9292-e987a64d42d0) created with:

  • Manufacturer: Xenia Coffee
  • Model: Xenia Espresso
  • Serial: 313253795029
  • SW Version: 3.9
  • Configuration URL: http://10.0.50.128

5 entities linked to the device: switch.xenia_power, switch.xenia_power_2, sensor.xenia_status, sensor.xenia_current_power_2, sensor.xenia_total_energy_2.

Key learnings:

  1. device_info does NOT work in rest: or template: YAML — confirmed by HA error messages
  2. Manual .storage/ device entries ARE persisted across restarts IF all required fields are present (see SKILL.md pitfall for complete field list)
  3. Entity-to-device links in .storage/core.entity_registry also survive restarts
  4. The rest: modern syntax (vs legacy sensor: - platform: rest) was adopted during this process — cleaner structure but still no device_info support

Power Switch Verification (confirmed 2026-06-29)

switch.xenia_power_2 turn_on/turn_off both work via HA API. Verified end-to-end:

  1. POST /api/services/switch/turn_on {"entity_id":"switch.xenia_power_2"} → switch state = on
  2. Device API confirms: MA_STATUS: 1, MA_CUR_PWR: 8.3W, temp rising (39.4°C → 48.4°C)
  3. POST /api/services/switch/turn_off {"entity_id":"switch.xenia_power_2"} → switch state = off
  4. Device API confirms: MA_STATUS: 0

Note: rest_command.xenia_machine_control also toggles power but returns empty response (not an error). The switch.xenia_power_2 REST switch is the cleaner interface.

Alexa Exposure

switch.xenia_power_2 is NOT exposed to Alexa via HA Cloud. The old switch.xenia_power (now dead) was likely the previously exposed entity. Fix: add switch.xenia_power_2 to HA Cloud Alexa exposure list, or use switch_as_x to create a light entity. Cannot fix via API alone — Alexa exposure list is managed in HA UI.

Configuration YAML (Modern rest: Syntax)

The configuration.yaml uses modern rest: integration syntax (converted from legacy sensor: - platform: rest):

rest:
  - resource: http://10.0.50.128/api/v2/overview
    method: GET
    timeout: 30
    scan_interval: 1
    sensor:
      - name: "Xenia Machine Data"
        unique_id: xenia_machine_data
        value_template: >-
          {% if value_json is defined %}OK{% else %}Error{% endif %}
        json_attributes:
          - MA_STATUS
          - BG_SENS_TEMP_A
          - BB_SENS_TEMP_A
          - PU_SENS_PRESS
          - SB_SENS_PRESS
          - MA_CUR_PWR
          - MA_ENERGY_TOTAL_KWH

  - resource: http://10.0.50.128/api/v2/overview_single
    method: GET
    timeout: 30
    scan_interval: 60
    sensor:
      - name: "Xenia Set Temperatures"
        unique_id: xenia_set_temperatures
        value_template: >-
          {% if value_json is defined %}OK{% else %}Error{% endif %}
        json_attributes:
          - BG_SET_TEMP

Template entities derive from these REST sensors and a template switch controls power via rest_command.