# Full EVCC config — Schön Consulting homelab
|
|
#
|
|
# Includes: grid meter, 3 PV inverters, 2 batteries, custom charger via HA,
|
|
# site config, Tibber tariff.
|
|
#
|
|
# Use this as a reference when modifying the EVCC config. Replace __HA_TOKEN__
|
|
# with a long-lived HA access token.
|
|
#
|
|
# Installation: Stop HA VM (qm stop 106), mount RBD disk, write to
|
|
# /mnt/haos/supervisor/homeassistant/evcc.yaml, unmount, start VM.
|
|
# Then restart EVCC add-on via Supervisor API.
|
|
#
|
|
# WARNING: EVCC add-on overwrites this file on restart. Stop VM, edit, start VM.
|
|
|
|
network:
|
|
schema: http
|
|
host: 0.0.0.0
|
|
port: 7070
|
|
|
|
log: info
|
|
interval: 30s
|
|
|
|
# ─── METERS (grid, PV, batteries) ───────────────────────────
|
|
|
|
meters:
|
|
# Grid meter — SMA Energy Meter via Modbus
|
|
- name: grid
|
|
type: custom
|
|
power:
|
|
source: modbus
|
|
id: 3
|
|
uri: 10.0.50.201:502
|
|
register:
|
|
address: 30865
|
|
type: input
|
|
decode: int32nan
|
|
energy:
|
|
source: modbus
|
|
id: 3
|
|
uri: 10.0.50.201:502
|
|
register:
|
|
address: 30529
|
|
type: input
|
|
decode: uint32nan
|
|
scale: 0.001
|
|
|
|
# PV inverter 1 — SMA via Modbus
|
|
- name: pv1
|
|
type: template
|
|
template: sma-inverter-modbus
|
|
usage: pv
|
|
modbus: tcpip
|
|
host: 10.0.50.201
|
|
port: 502
|
|
|
|
# PV inverter 2 — SMA via Modbus
|
|
- name: pv2
|
|
type: template
|
|
template: sma-inverter-modbus
|
|
usage: pv
|
|
modbus: tcpip
|
|
host: 10.0.50.203
|
|
port: 502
|
|
|
|
# SMA Sunny Boy Storage battery via Modbus
|
|
- name: battery
|
|
type: template
|
|
template: sma-sbs-modbus
|
|
usage: battery
|
|
modbus: tcpip
|
|
host: 10.0.50.202
|
|
port: 502
|
|
maxchargepower: 4200
|
|
watchdog: 60s
|
|
|
|
# Marstek Venus E battery — bridged through HA REST API
|
|
# Direct Modbus (10.0.50.113:502) is closed from EVCC's network.
|
|
# HA's Marstek Modbus integration reads it fine, so bridge via HA entities.
|
|
# NOTE: Do NOT add 'usage: battery' — custom type doesn't accept it.
|
|
# The 'soc:' field implicitly marks this as a battery.
|
|
- name: marstek
|
|
type: custom
|
|
capacity: 5
|
|
maxchargepower: 2500
|
|
maxdischargepower: 2500
|
|
power:
|
|
source: http
|
|
uri: http://10.0.30.10:8123/api/states/sensor.marstek_venus_modbus_ac_leistung
|
|
headers:
|
|
Authorization: "Bearer __HA_TOKEN__"
|
|
jq: '.state | tonumber'
|
|
soc:
|
|
source: http
|
|
uri: http://10.0.30.10:8123/api/states/sensor.marstek_venus_modbus_batterie_ladezustand
|
|
headers:
|
|
Authorization: "Bearer __HA_TOKEN__"
|
|
jq: '.state | tonumber'
|
|
energy:
|
|
source: http
|
|
uri: http://10.0.30.10:8123/api/states/sensor.marstek_venus_modbus_gesamte_entladeenergie
|
|
headers:
|
|
Authorization: "Bearer __HA_TOKEN__"
|
|
jq: '.state | tonumber'
|
|
|
|
# Hoymiles micro-inverter via OpenDTU
|
|
- name: hoymiles
|
|
type: template
|
|
template: hoymiles-opendtu
|
|
usage: pv
|
|
host: 10.0.40.55
|
|
|
|
# ─── CHARGER (custom, bridged through HA REST API) ──────────
|
|
# SMA EV Charger (10.0.50.205) — direct connection fails (TLS cert
|
|
# without IP-SANs, SMA API returns 400). Native HA SMA integration
|
|
# works via different network path. Bridge through HA entities.
|
|
|
|
chargers:
|
|
- name: wallbox
|
|
type: custom
|
|
status:
|
|
source: http
|
|
uri: http://10.0.30.10:8123/api/states/sensor.ev_charger_schon_status_ladevorgang
|
|
headers:
|
|
Authorization: "Bearer __HA_TOKEN__"
|
|
jq: 'if .state == "active_mode" then "C" elif .state == "sleep_mode" then "B" elif .state == "not_connected" then "A" else "F" end'
|
|
enabled:
|
|
source: http
|
|
uri: http://10.0.30.10:8123/api/states/switch.ev_charger_schon_manuelle_ladefreigabe
|
|
headers:
|
|
Authorization: "Bearer __HA_TOKEN__"
|
|
jq: '.state == "on"'
|
|
enable:
|
|
source: http
|
|
uri: http://10.0.30.10:8123/api/services/switch/{{ if .enable }}turn_on{{ else }}turn_off{{ end }}
|
|
method: POST
|
|
headers:
|
|
Authorization: "Bearer __HA_TOKEN__"
|
|
Content-Type: application/json
|
|
body: '{"entity_id": "switch.ev_charger_schon_manuelle_ladefreigabe"}'
|
|
maxcurrent:
|
|
source: http
|
|
uri: http://10.0.30.10:8123/api/services/number/set_value
|
|
method: POST
|
|
headers:
|
|
Authorization: "Bearer __HA_TOKEN__"
|
|
Content-Type: application/json
|
|
body: '{"entity_id": "number.ev_charger_schon_ac_strom_begrenzung", "value": {{.maxcurrent}}}'
|
|
power:
|
|
source: http
|
|
uri: http://10.0.30.10:8123/api/states/sensor.ev_charger_schon_leistung_ladestation
|
|
headers:
|
|
Authorization: "Bearer __HA_TOKEN__"
|
|
jq: '.state | tonumber'
|
|
energy:
|
|
source: http
|
|
uri: http://10.0.30.10:8123/api/states/sensor.ev_charger_schon_zahlerstand_ladestation
|
|
headers:
|
|
Authorization: "Bearer __HA_TOKEN__"
|
|
jq: '.state | tonumber'
|
|
scale: 0.001
|
|
|
|
# ─── LOADPOINT ──────────────────────────────────────────────
|
|
|
|
loadpoints:
|
|
- title: Wallbox
|
|
charger: wallbox
|
|
mode: pv
|
|
phases: 0
|
|
mincurrent: 6
|
|
maxcurrent: 16
|
|
enable:
|
|
threshold: 0
|
|
delay: 1m
|
|
disable:
|
|
threshold: 500
|
|
delay: 3m
|
|
|
|
# ─── SITE ───────────────────────────────────────────────────
|
|
|
|
site:
|
|
title: Zuhause
|
|
meters:
|
|
grid: grid
|
|
pv:
|
|
- pv1
|
|
- pv2
|
|
- hoymiles
|
|
battery:
|
|
- battery
|
|
- marstek
|
|
residualPower: 100
|
|
|
|
# ─── TARIFFS ────────────────────────────────────────────────
|
|
|
|
tariffs:
|
|
currency: EUR
|
|
grid:
|
|
type: tibber
|
|
token: "__TIBBER_TOKEN__"
|