Auto-sync: 2026-10-08
This commit is contained in:
@@ -3,7 +3,7 @@ title: "EMHASS Kaskaden-Automations-Architektur"
|
||||
category: reference
|
||||
tags: [emhass, battery, cascade, homeassistant, byd, marstek]
|
||||
created: "2026-10-02"
|
||||
modified: "2026-10-02"
|
||||
modified: "2026-10-08"
|
||||
---
|
||||
|
||||
# EMHASS Kaskaden-Automations-Architektur
|
||||
@@ -104,9 +104,23 @@ Siehe Solution Doc: `docs/solutions/integrations/2026-10-02-emhass-set-config-ov
|
||||
| Job ID | Schedule | Typ | Funktion |
|
||||
|--------|----------|-----|----------|
|
||||
| `a32005d62226` | every 15m | no_agent script | Ruft EMHASS Optimization auf, published Plan zu HA |
|
||||
| `d046e808f543` | */15m | LLM-Agent (silent-on-healthy) | Shadow-Dual-Solve A/B + Ledger |
|
||||
| `19aef2351273` | hourly :35 | no_agent script | Shadow-Staleness-Watchdog (>45 min -> Alert) |
|
||||
|
||||
Runner: `/home/debian/.hermes/scripts/emhass-optimizer-runner.sh`
|
||||
Optimizer: `/home/debian/scripts/emhass_optimizer.py`
|
||||
Shadow: `/home/debian/scripts/emhass_optimizer_v2.py --shadow` - Ledger `~/shadow_phase2/ledger.jsonl` - Report `~/scripts/report_phase2.py`
|
||||
|
||||
## Shadow Phase-2 (live seit 2026-10-08)
|
||||
|
||||
Dual-Solve-Validierung (A=Standard, B=grid-charge erlaubt) auf IDENTISCHEN
|
||||
Inputs; Incumbent unangetastet. Bewiesene CSV-Gesetze: `+P`=Entladung,
|
||||
`P_grid` signed net import (**Export NEGATIV**), Deferrable-Spalten =
|
||||
Phantom-Last (+12 kWh Summeninvarianz, KEINE Consumer) ->
|
||||
**produktiv entfernt 2026-10-08** (`number_of_deferrable_loads: 2->0`,
|
||||
Direct-File-Edit + Addon-Restart im :50-Fenster, Backup
|
||||
`config.json.hermesbak-20261008`; Beweis: Incumbent-CSV faellt auf 17
|
||||
Spalten). Auswertung: `python3 ~/scripts/report_phase2.py`.
|
||||
|
||||
## Deaktivierte Komponenten
|
||||
|
||||
|
||||
@@ -0,0 +1,141 @@
|
||||
---
|
||||
title: "EMHASS Kaskaden-Automations-Architektur"
|
||||
category: reference
|
||||
tags: [emhass, battery, cascade, homeassistant, byd, marstek]
|
||||
created: "2026-10-02"
|
||||
modified: "2026-10-02"
|
||||
---
|
||||
|
||||
# EMHASS Kaskaden-Automations-Architektur
|
||||
|
||||
> Steuerung der dualen Batterie-Systems (BYD 11kWh + Marstek 5kWh) via EMHASS Optimizer + HA Kaskaden-Automation.
|
||||
|
||||
## Architektur-Übersicht
|
||||
|
||||
```
|
||||
EMHASS (LP Solver) → sensor.smart_battery_target
|
||||
↓
|
||||
┌───────────────────┴──────────────────┐
|
||||
│ Kaskaden-Automation (jede 2 Min) │
|
||||
├───────────────────────────────────────┤
|
||||
│ BYD/SMA: 803 Auto (default) │
|
||||
│ 802 Manual (bei target≤0) │
|
||||
│ Marstek: force_mode via │
|
||||
│ sensor.marstek_target_power │
|
||||
│ (= smart_target − BYD_actual)│
|
||||
└───────────────────────────────────────┘
|
||||
```
|
||||
|
||||
## EMHASS Configuration (16 kWh Virtual Battery)
|
||||
|
||||
| Parameter | Value | Hinweis |
|
||||
|-----------|-------|---------|
|
||||
| `battery_nominal_energy_capacity` | 16000 | BYD 11k + Marstek 5k kombiniert |
|
||||
| `battery_charge_power_max` | 6700 | 4200 (BYD) + 2500 (Marstek) |
|
||||
| `battery_discharge_power_max` | 6700 | dto. |
|
||||
| `battery_charge_efficiency` | 0.9 | Konservativ, gemischt |
|
||||
| `battery_discharge_efficiency` | 0.9 | dto. |
|
||||
| `battery_target_state_of_charge` | 0.15 | 15% Reserve (geändert von 0.30 am 2026-10-02) |
|
||||
| `battery_soc_deficit_cost` | 0.5 | Strafe für Unterschreitung |
|
||||
| `battery_minimum_state_of_charge` | 0.1 | 10% Hard Floor |
|
||||
| `battery_maximum_state_of_charge` | 1.0 | 100% |
|
||||
| `set_battery_dynamic` | True | Dynamische Peeling erlaubt |
|
||||
| `set_use_battery` | True | Batterie aktiv |
|
||||
| `sensor_battery_state_of_charge` | `sensor.total_soc` | Gewichteter Gesamt-SoC |
|
||||
| `sensor_power_battery` | `sensor.batteries_power_out_total` | Entladeleistung |
|
||||
| `use_websocket` | True | |
|
||||
|
||||
## ⚠️ Known Pitfall: set-config Full Overwrite
|
||||
|
||||
`POST /set-config` ersetzt die **gesamte** Konfiguration, nicht nur gesendete Felder.
|
||||
Nicht angegebene Parameter fallen auf Defaults zurück (capacity→5000, power→1000, etc.).
|
||||
|
||||
**Regel:** Immer ALLE Parameter zusammen senden. Nach jedem Write mit `GET /get-config` verifizieren.
|
||||
|
||||
Siehe Solution Doc: `docs/solutions/integrations/2026-10-02-emhass-set-config-overwrite-pitfall.md`
|
||||
|
||||
## Kaskaden-Automation
|
||||
|
||||
**Automation ID:** `1774430238377` (ON)
|
||||
**Schedule:** Alle 2 Minuten
|
||||
**File:** `/mnt/data/supervisor/homeassistant/automations.yaml`
|
||||
|
||||
### BYD/SMA Steuerung
|
||||
|
||||
| EMHASS target | PV | BYD Modus | Bedeutung |
|
||||
|--------------|-----|-----------|-----------|
|
||||
| `> 0` (Entladung) | egal | **803 Auto** | BYD self-managed, Marstek kriegt Rest |
|
||||
| `≤ 0` (Hold/Ladung) | `< 100W` | **802 Manual** | BYD hält/zwingt Ladung, EVCC hold |
|
||||
| `< 0` (Ladung) | `≥ 100W` | **803 Auto** | PV reicht, BYD lädt selbst |
|
||||
|
||||
- BYD läuft permanent in Auto/Normal — nur bei EMHASS-Hold/Zwangsladung auf 802
|
||||
- Modbus Register: 44425 (Mode), 44427 (Power)
|
||||
- BYD IP: `10.0.50.202:502`
|
||||
|
||||
### Marstek Steuerung
|
||||
|
||||
- `sensor.marstek_target_power` = `smart_battery_target − actual_BYD_discharge + actual_BYD_charge`
|
||||
- Cap: ±2500W
|
||||
- Force modes: `charge`, `discharge`, `standby`
|
||||
- Writable entities: `select.marstek_venus_modbus_force_mode`,
|
||||
`number.marstek_venus_modbus_ladeleistung_einstellen`,
|
||||
`number.marstek_venus_modbus_entladeleistung_einstellen`
|
||||
- Marstek IP: `10.0.50.113`
|
||||
|
||||
### Gelöste Bugs
|
||||
|
||||
1. **Double-Counting (behoben 2026-10-01):** `sensor.sma_target_power` nahm volle EMHASS-Target,
|
||||
ließ Marstek 0W. Fix: `sma_target_power` gelöscht, `marstek_target_power` nutzt jetzt
|
||||
echte BYD-Werte (discharge - charge) statt Forecast-Split.
|
||||
2. **Overnight Hold Too High (behoben 2026-10-02):** EMHASS hielt bei 65% weil
|
||||
`target_state_of_charge=0.30`. Geändert auf 0.15.
|
||||
3. **BYD ignoriert Hold (behoben 2026-10-02):** 802-Bedingung war `target < 0`,
|
||||
jetzt `target <= 0` (Hold bei target=0 eingeschlossen).
|
||||
|
||||
## Template Sensoren (configuration.yaml)
|
||||
|
||||
- `sensor.smart_battery_target` — EMHASS p_batt_forecast, gerundet
|
||||
- `sensor.marstek_target_power` — Plan A: smart_target − actual_BYD_net_discharge
|
||||
- Guards: SoC-Checks, ±2500W cap
|
||||
- `sensor.sma_target_power` — **ENTFERNT** (war Double-Counting Source)
|
||||
|
||||
## Cron Jobs
|
||||
|
||||
| Job ID | Schedule | Typ | Funktion |
|
||||
|--------|----------|-----|----------|
|
||||
| `a32005d62226` | every 15m | no_agent script | Ruft EMHASS Optimization auf, published Plan zu HA |
|
||||
|
||||
Runner: `/home/debian/.hermes/scripts/emhass-optimizer-runner.sh`
|
||||
Optimizer: `/home/debian/scripts/emhass_optimizer.py`
|
||||
|
||||
## Deaktivierte Komponenten
|
||||
|
||||
| Component | Status | Grund |
|
||||
|-----------|--------|-------|
|
||||
| Tibber Smart Charging Bridge | OFF | EMHASS ist sole optimizer |
|
||||
| Marstek Kaskaden-Steuerung (Modbus) | OFF | Alte PV-only Kaskade, ersetzt durch EMHASS-Kaskade |
|
||||
|
||||
## Hardware Referenz
|
||||
|
||||
| Device | IP | Capacity | Max Power | Interface |
|
||||
|--------|----|----------|-----------|-----------|
|
||||
| BYD/SMA SBS | 10.0.50.202:502 | 11 kWh | 4.2 kW | Modbus 44425/44427 |
|
||||
| Marstek Venus E | 10.0.50.113 | 5 kWh | 2.5 kW | HA Entities (Modbus) |
|
||||
| SMA SB #1 | 10.0.50.201:502 | — | — | PV Wechselrichter |
|
||||
| SMA SB #2 | 10.0.50.203:502 | — | — | PV Wechselrichter |
|
||||
| Hoymiles | 10.0.40.55 | — | — | OpenDTU |
|
||||
|
||||
## Zugriff
|
||||
|
||||
- EMHASS API: `http://10.0.30.10:5000`
|
||||
- HA intern: `http://10.0.30.10:8123`
|
||||
- HA extern: `https://homeassistant.familie-schoen.com`
|
||||
- SSH: `ssh -i ~/.ssh/id_ed25519_proxmox -p 22222 root@10.0.30.10`
|
||||
- HA Token: `/tmp/ha_token.txt`
|
||||
- HA Config: `/mnt/data/supervisor/homeassistant/`
|
||||
- Backups: `.bak.20261001_175804` (configuration.yaml + automations.yaml)
|
||||
|
||||
## Related
|
||||
|
||||
- [[systems/homeassistant]] — HA System Seite
|
||||
- Solution Doc: `docs/solutions/integrations/2026-10-02-emhass-set-config-overwrite-pitfall.md`
|
||||
+2
-2
@@ -17,8 +17,8 @@ modified: "2026-09-30"
|
||||
| 10.0.20.60 | proxmox6 | 6 | |
|
||||
| 10.0.20.70 | proxmox7 | 7 | MON, Traefik CT99999 |
|
||||
| 10.0.20.91 | n5pro | 8 | Templates 9000/9001/9002, MON, MGR (active) |
|
||||
| 10.0.20.92 | ms-a2-1 | 9 | OSD 13 (SSD 1.8TB), GPU 1002:13c0, MON, **NUT-Server (APC UPS USB, :3493)** |
|
||||
| 10.0.20.93 | ms-a2-2 | 1 | OSD 14 (SSD 1.8TB), GPU 1002:13c0 |
|
||||
| 10.0.20.92 | ms-a2-1 | 9 | OSD 13 (SSD 1.8TB), GPU 1002:13c0, MON, **NUT-Master (APC UPS USB, upsd :3493, Shutdown-Kaskade)** |
|
||||
| 10.0.20.93 | ms-a2-2 | 1 | OSD 14 (SSD 1.8TB), GPU 1002:13c0, NUT-Slave |
|
||||
|
||||
> ⚠️ n5pro (10.0.20.91, nodeid 8) ≠ proxmox7 (10.0.20.70, nodeid 7) — separate Nodes!
|
||||
> proxmox1 (10.0.20.10) und proxmox2 (10.0.20.20) wurden dauerhaft entfernt.
|
||||
|
||||
Reference in New Issue