@@ -64,7 +64,22 @@ modified: "2026-09-27"
|
||||
- Marstek Speicher (VENUS-E, IP 10.0.50.113)
|
||||
- Various sensors (Xiaomi BLE, etc.)
|
||||
|
||||
## EMHASS Batteriesteuerung
|
||||
- **Endpoint:** `http://10.0.30.10:5000` (v0.18.4)
|
||||
- **Architektur:** EMHASS = Sole Optimizer. Virtuelle 16 kWh Batterie (BYD 11k + Marstek 5k).
|
||||
- **Config API:** `POST /set-config` überschreibt GESAMTE Konfig (kein Partial-Update!). Immer alle Felder senden. Siehe Solution Doc `integrations/2026-10-02-emhass-set-config-overwrite-pitfall.md`.
|
||||
- **Akuelle Config (2026-10-02):**
|
||||
- Capacity 16000Wh, Charge/Discharge 6700W, Efficiency 0.9
|
||||
- Target SoC 0.15 (15%), Min SoC 0.1, Max SoC 1.0
|
||||
- `set_battery_dynamic: True`, `set_use_battery: True`
|
||||
- SoC sensor: `sensor.total_soc`, Power sensor: `sensor.batteries_power_out_total`
|
||||
- **Kaskaden-Automation** (`1774430238377`, ON): EMHASS target → BYD (803 Auto default, 802 bei `target<=0 && pv<100`) + Marstek (Rest via `sensor.marstek_target_power`)
|
||||
- **Template Sensoren:** `sensor.smart_battery_target` (EMHASS), `sensor.marstek_target_power` (Plan A: smart_target − actual_BYD_discharge). `sensor.sma_target_power` ENTFERNT (Double-Counting Bug).
|
||||
- **Cron:** `a32005d62226` (no_agent, every 15m, runner script) ruft EMHASS Optimization auf.
|
||||
- **Backup:** `.bak.20261001_175804` für configuration.yaml + automations.yaml
|
||||
|
||||