- New: smart-home/home-assistant-dashboard-conventions (Mushroom cards, view tabs, no Bubble Cards) - Updated: rke2, ceph, galera, proxmox, brainstorming, compound-learning, 1password-cli, smart-home-automation skills - New references: ceph-cluster-administration, docker-volume-forensics, ceph-crush-weight, ceph-ec-mixed-size
11 KiB
Creating a Ceph OSD via Hot-Plug on Non-PVE Nodes (n5pro / Minisforum)
When to Use
Adding a new HDD OSD to a Ceph cluster by physically hot-plugging a SATA
drive into a running node that is not a standard PVE host (e.g. Minisforum
N5 PRO with JMB58x SATA controller, CRUSH host n5pro).
Prerequisites Checklist
- Drive is physically inserted (hot-plug or powered-off install)
- Node has
ceph,ceph-volume,pvecephinstalled - Node has
/etc/ceph/ceph.confandceph.client.admin.keyring /etc/ceph/ceph.confis a symlink to/etc/pve/ceph.conf
Step-by-Step
1. Detect the Hot-Plugged Drive
If the drive was inserted while the node was running, the SATA bus may not auto-scan. Trigger a manual rescan:
for h in /sys/class/scsi_host/host{0,1,2,3,4}; do
echo "- - -" > ${h}/scan
done
sleep 2
lsblk -d -o NAME,MODEL,SERIAL,SIZE,TRAN,ROTA,STATE | grep -v rbd | grep -v loop
Verify the drive appears (e.g. /dev/sdb, MODEL=WDC WD30EFZX).
2. Copy Ceph Config to Non-PVE Node (if missing)
If the node lacks /etc/ceph/ceph.conf or the admin keyring:
# From PVE master (10.0.20.10), copy to target node:
scp /etc/ceph/ceph.conf root@<node>:/etc/ceph/
scp /etc/ceph/ceph.client.admin.keyring root@<node>:/etc/ceph/
ssh root@<node> 'chmod 644 /etc/ceph/ceph.conf && chmod 600 /etc/ceph/ceph.client.admin.keyring'
3. Fix ceph.conf Symlink (CRITICAL — pveceph requires it)
pveceph osd create refuses to run if /etc/ceph/ceph.conf is a regular
file rather than a symlink to /etc/pve/ceph.conf:
file '/etc/ceph/ceph.conf' already exists and is not a symlink to /etc/pve/ceph.conf
Fix:
rm /etc/ceph/ceph.conf
ln -s /etc/pve/ceph.conf /etc/ceph/ceph.conf
4. Zap the Drive Clean
Remove any leftover partitions/filesystem signatures from prior use:
sgdisk --zap-all /dev/sdX
wipefs -a /dev/sdX
parted /dev/sdX mklabel gpt
lsblk /dev/sdX -o NAME,SIZE,TYPE,FSTYPE,MOUNTPOINT # verify clean
5. Create the OSD
pveceph osd create /dev/sdX
This runs ceph-volume lvm create internally: creates a VG + LV on the
disk, formats BlueStore, registers with the MON, enables systemd services
(ceph-volume@lvm-<id>-<uuid>.service, ceph-osd@<id>.service), and
starts the OSD.
6. Wait for OSD to Come Up (10-15 seconds)
The newly created OSD will initially show as down in ceph osd tree.
The ceph-osd@<id> service is running but waits for the OSD map to load.
Wait ~15 seconds, then verify:
ceph osd tree | grep osd.<id>
# Should show: up 1.00000
If still down after 30s, check:
journalctl -u ceph-osd@<id> --no-pager -n 30
systemctl status ceph-osd@<id>
Common non-fatal log lines:
failed to load OSD map for epoch N, got 0 bytes— transient, resolvesset_numa_affinity unable to identify public interface— cosmetic
7. Verify Cluster Integration
ceph osd crush get-device-class osd.<id> # should report 'hdd'
ceph -s # OSD count increased
ceph df # raw capacity increased
Rebalancing begins automatically — expect a spike in remapped_pgs (normal).
Pitfalls
pveceph osd create fails: "already exists and is not a symlink"
Symptom: pveceph osd create /dev/sdb exits with code 22 and the
message file '/etc/ceph/ceph.conf' already exists and is not a symlink.
Cause: On non-standard PVE nodes (e.g. n5pro), /etc/ceph/ceph.conf
was manually placed as a regular file. pveceph insists on it being a
symlink to /etc/pve/ceph.conf.
Fix: Remove the file and create the symlink (step 3 above).
Hot-Plugged SATA Drive Not Detected
Symptom: Drive physically inserted but lsblk doesn't show it.
Cause: The JMB58x AHCI controller does not expose hot_plug sysfs
attribute, and Linux may not auto-scan the port.
Fix: Manual SCSI host rescan (step 1 above). The JMB58x does support AHCI hot-plug electrically even though the sysfs attribute is absent.
OSD Shows "down" Immediately After Creation
Symptom: ceph osd tree shows the new OSD as down with weight 0.
Cause: The ceph-osd daemon takes 10-15 seconds to load the OSD map
and register with the MONs. This is normal startup latency, not a failure.
Fix: Wait. Check systemctl status ceph-osd@<id> — if it says
active (running), the OSD will come up shortly.
Bootstrap Keyring Warning During ceph-volume
Symptom: unable to find a keyring on /etc/pve/priv/ceph.client.bootstrap-osd.keyring
Cause: The bootstrap-osd keyring lives elsewhere on some nodes. The
warning is non-fatal — ceph-volume falls back to the admin keyring.
Fix: None needed. OSD creation succeeds despite this warning.
Hardware Notes: Minisforum N5 PRO
| Spec | Value |
|---|---|
| SATA Controller | JMicron JMB58x AHCI, 5 ports |
| AHCI Version | 1.0301, 32 command slots, 6 Gbps |
| AHCI Flags | ncq sntf stag pm led clo pmp fbs pio slum part ccc apst boh |
| Hot-Plug sysfs | hot_plug attribute NOT exposed |
| Actual Hot-Plug | Works — bus rescan detects the drive |
| CRUSH Host Name | n5pro (own bucket, NOT ubuntu) |
| Existing OSDs | NONE — n5pro starts with zero OSDs |
| NVMe | AirDisk 128GB SSD (boot + LVM VG pve with WAL/DB LVs) |
CRITICAL — n5pro ≠ ubuntu: Host
ubuntu(IP 10.0.30.100) is a SEPARATE machine with its own OSDs (osd.6, osd.8). n5pro (IP 10.0.20.91) must have its own CRUSH host bucket namedn5pro. Do NOT place n5pro OSDs underubuntu— this would falsely suggest geographic separation for replicas that are actually on the same physical node.
Adding SSD WAL/DB to an OSD on Non-PVE Nodes
When the OSD's HDD is on a node that also has an NVMe SSD, placing the
BlueStore DB (and collocated WAL) on the SSD dramatically improves write
performance. The n5pro has a 128 GB AirDisk NVMe (/dev/nvme0n1) with
an LVM VG pve that can host WAL/DB LVs.
Creating WAL/DB LVs on the NVMe
# Check free space in the pve VG
vgs pve # look at VFree
# Create 30 GB LV for WAL/DB (one per OSD)
lvcreate -L 30G -n wal-db-osd-a pve
# Optional second LV for a future OSD:
lvcreate -L 30G -n wal-db-osd-b pve
⚠️ pveceph Cannot Use LVM Devices for WAL
pveceph osd create /dev/sdb --wal_dev /dev/pve/wal-db-osd-a FAILS:
unable to get device info for '/dev/dm-2' for type wal_dev
pveceph expects a raw block device, not a device-mapper LV. Use
ceph-volume directly instead.
⚠️ BlueStore Cannot Share One LV For Both WAL and DB Separately
Specifying --block.wal AND --block.db pointing to the SAME LV fails:
bdev(...) open got: (16) Device or resource busy
bluestore _minimal_open_bluefs add block device(block.wal) returned: (16) Device or resource busy
OSD::mkfs: ObjectStore::mkfs failed with error (5) Input/output error
BlueStore opens the WAL device exclusively — it cannot be the same underlying device as DB. The rollback also destroys the WAL LV.
✅ Correct Method: ceph-volume with --block.db Only
Specify ONLY --block.db — BlueStore collocates WAL on the DB device
automatically. This is the standard approach for a single shared SSD:
# 1. Ensure the WAL/DB LV exists
lvcreate -L 30G -n wal-db-osd-a pve
# 2. Prepare the OSD with DB on NVMe (WAL collocated)
ceph-volume lvm prepare --bluestore \
--data /dev/sdb \
--block.db /dev/pve/wal-db-osd-a
# 3. Activate the OSD (replace UUID from prepare output)
ceph-volume lvm activate <osd_id> <osd_uuid>
# 4. Verify DB/WAL placement
ceph-volume lvm list <osd_id>
# Should show:
# [block] /dev/ceph-<vg>/osd-block-<uuid> (data on HDD)
# [db] /dev/pve/wal-db-osd-a (DB on NVMe)
# db device /dev/pve/wal-db-osd-a
# devices /dev/nvme0n1p3
Destroy and Recreate an OSD With WAL
If an OSD was already created WITHOUT WAL and needs to be rebuilt:
# 1. Stop the OSD service
systemctl stop ceph-osd@<id>
# 2. Mark down and destroy
ceph osd down <id>
ceph osd destroy <id> --yes-i-really-mean-it
# 3. Zap the disk (removes VG, LV, BlueStore signatures)
ceph-volume lvm zap /dev/sdX --destroy
# 4. Recreate with WAL/DB as above
CRUSH Host Assignment for Non-PVE Nodes
When using ceph-volume (not pveceph), the OSD may land in the wrong
CRUSH host or under a generic bucket. Verify and fix:
# Check which host the OSD landed in
ceph osd tree | grep osd.<id>
# If in wrong host, move it:
ceph osd crush set osd.<id> <weight> root=default host=<correct_hostname>
# Set device class if not auto-detected
ceph osd crush set-device-class hdd osd.<id>
# Remove old destroyed OSD from CRUSH
ceph osd crush remove osd.<old_id>
ceph osd rm <old_id>
Session Log — 2026-07-13
Phase 1: Initial OSD Creation (osd.9, no WAL)
Added osd.9 (WD Red Plus 3 TB, WD-WX22DA0D7EP3) to n5pro via hot-plug.
Drive was removed from CT 10.0.30.100 and physically inserted into n5pro
while running. Bus rescan detected it on ata5. Created as BlueStore OSD
with pveceph osd create /dev/sdb. Cluster went from 10→11 OSDs.
backfill_toofull PGs dropped from 9→1 immediately. Remapped PGs spiked
to 317 (expected rebalance). Device class: hdd.
Phase 2: CRUSH Host Correction
Mistake: Initially moved osd.6+osd.8 from host ubuntu to n5pro,
assuming they were on the same machine. User corrected: osd.6 and
osd.8 belong to host ubuntu (10.0.30.100), a separate physical machine.
n5pro (10.0.20.91) only hosts osd.9 (later osd.11).
Fixed by recreating the ubuntu bucket and moving osd.6+osd.8 back:
ceph osd crush add-bucket ubuntu host
ceph osd crush move ubuntu root=default
ceph osd crush set osd.6 2.75829 root=default host=ubuntu
ceph osd crush set osd.8 2.72899 root=default host=ubuntu
Phase 3: Rebuild with SSD WAL/DB (osd.9 → osd.11)
Destroyed osd.9 (created without WAL) and rebuilt as osd.11 with DB on NVMe SSD. Key steps:
systemctl stop ceph-osd@9→ceph osd destroy 9→ceph-volume lvm zap /dev/sdb --destroy- Attempted
ceph-volume lvm prepare --bluestore --data /dev/sdb --block.wal /dev/pve/wal-db-osd-a --block.db /dev/pve/wal-db-osd-a→ FAILED (device busy, same LV for WAL+DB) - Rollback deleted
wal-db-osd-aLV — had to recreate withlvcreate -L 30G -n wal-db-osd-a pve - Succeeded with
--block.db /dev/pve/wal-db-osd-aonly (WAL collocated on DB) - Activated, verified DB on NVMe, set CRUSH host to
n5pro, device classhdd - Removed old osd.9 from CRUSH:
ceph osd crush remove osd.9+ceph osd rm 9
Final osd.11: data on /dev/sdb (3 TB HDD), DB+WAL on /dev/pve/wal-db-osd-a
(30 GB NVMe LV), CRUSH host n5pro, weight 2.76, device class hdd.