# Ceph Recovery Acceleration — Advanced Tuning — 2026-07-05
## Context
Follow-up to `ceph-pool-full-recovery-2026-07.md`. After unblocking backfill by raising `backfillfull_ratio` and reweighting OSD 7, recovery was progressing but slowly (22 MiB/s, 5 obj/s, only 2 PGs backfilling). This session applied additional tuning to accelerate recovery.
## Additional Recovery Parameters
### `osd_recovery_op_priority` (effective)
```bash
# Set globally via MON config
ceph config set osd osd_recovery_op_priority 10
# Default: 3. Range: 1-63. Higher = recovery ops preempt client ops.
# Verify on running OSD:
ceph daemon osd.7 config get osd_recovery_op_priority
# Returns: {"osd_recovery_op_priority": "10"}
```
Unlike `osd_max_backfills`, this one DOES apply at runtime via `ceph config set` — no restart needed. OSDs pick it up within seconds.
### `osd_recovery_sleep` (set to 0)
```bash
ceph config set osd osd_recovery_sleep 0
# Default: 0.001 (1ms pause between recovery ops). Set to 0 for maximum throughput.
```
### `osd_recovery_max_chunk`
```bash
ceph config set osd osd_recovery_max_chunk 104857600
# Default: 8MiB. Set to 100MiB for larger transfer windows.
```
### `ceph tell osd.N config set` — Alternative to `injectargs`
Newer Ceph (Reef/Squid) supports `ceph tell osd.N config set` as a cleaner alternative to `injectargs`:
```bash
# Instead of: ceph tell osd.7 injectargs "--osd_max_backfills 3"
# Use:
ceph tell osd.7 config set osd_max_backfills 3
```
However, in testing, `ceph config set osd osd_max_backfills 3` (MON-level) did NOT propagate to running OSDs — the OSDs kept using value 1. The `ceph tell osd.N config set` also didn't reliably stick. The most reliable method remains:
```bash
# Most reliable runtime method:
ceph tell osd.7 injectargs "--osd_max_backfills 3"
# Verify:
ceph daemon osd.7 config get osd_max_backfills
# Must return "3" — if still "1", the config hasn't been applied.
```
### UPDATE 2026-07-13: `ceph tell osd.* config set` DOES Work
In a follow-up session, `ceph tell osd.* config set osd_max_backfills 3`
DID successfully apply to running OSDs. Verification:
```bash
ceph tell osd.11 config get osd_max_backfills
# Returns: {"osd_max_backfills": "3"}
```
The difference from the earlier session: `ceph config set osd osd_max_backfills 3`
(MON-level persistent config) was set FIRST, then `ceph tell osd.* config set`
was used to push it to running OSDs. The combination worked. Injectargs
returned empty `{}` (appeared to fail) but the config took effect.
**Recommendation**: Use BOTH `ceph config set` (persistent for future OSDs)
AND `ceph tell osd.* config set` (runtime for current OSDs). Then verify
with `ceph tell osd.N config get`.
### `osd_recovery_max_active` — NOT effectively tunable
`ceph config set osd osd_recovery_max_active 3` accepts the value but OSDs report 0 (meaning auto/default). `injectargs` also shows empty. This appears to be a Ceph limitation — the parameter is managed internally. Do not waste time trying to force it.
## Full Recovery Tuning Recipe
```bash
# 1. Unblock backfill (if backfillfull)
ceph osd set-backfillfull-ratio 0.97
ceph osd set-nearfull-ratio 0.97
# 2. Reweight overfull OSD
ceph osd crush reweight osd.7 0.50
# 3. Set recovery parameters via MON config (applies to new/restarted OSDs)
ceph config set osd osd_max_backfills 3
ceph config set osd osd_recovery_op_priority 10
ceph config set osd osd_recovery_sleep 0
ceph config set osd osd_recovery_max_chunk 104857600
# 4. Force runtime application on each HDD OSD (MON config doesn't propagate to running OSDs)
for osd in 1 6 7 8 10; do
ceph tell osd.$osd injectargs "--osd_max_backfills 3"
ceph tell osd.$osd injectargs "--osd_recovery_op_priority 10"
done
# 5. Verify each OSD picked up the config
for osd in 1 6 7 8 10; do
echo "=== osd.$osd ==="
ceph daemon osd.$osd config get osd_max_backfills
ceph daemon osd.$osd config get osd_recovery_op_priority
done
```
## Recovery Speed Progression
| Stage | Recovery Speed | Concurrent Backfills | Notes |
|-------|---------------|---------------------|-------|
| Before intervention | 0 MiB/s (stuck) | 0 | backfillfull blocks all |
| After ratio + reweight | 22-23 MiB/s, 5 obj/s | 1-2 | Backfill unblocked |
| After injectargs (max_backfills=3) | 34 MiB/s, 8 obj/s | 2-3 | Even with max=3, Ceph schedules conservatively |
| After op_priority=10 + sleep=0 | ~34 MiB/s, 8 obj/s | 2-3 | Priority helps under client I/O load |
Even with `osd_max_backfills=3`, expect only 2-3 PGs backfilling simultaneously — Ceph schedules conservatively. The throughput improvement comes from larger transfer windows and reduced pauses, not dramatically more parallel PGs.
## OSD Restart Considerations
If `injectargs` doesn't work, restarting the OSD daemon forces it to pick up the MON config:
```bash
# ⚠️ MUST restart on the correct node! Use ceph osd find to locate:
ceph osd find 7
# Returns JSON with host name and IP
# SSH to THAT node and restart:
ssh root@<correct_node_ip> "systemctl restart ceph-osd@7"
# ❌ WRONG: restarting on a node that doesn't host the OSD →
# "OSD data directory /var/lib/ceph/osd/ceph-7 does not exist; bailing out"
# After restart, OSD goes through peering — may take 30-60s
# During peering, PGs may show as "peering" or "activating"
```
## Monitoring Recovery
```bash
# Quick status
ceph -s | grep -E "osd:|pgs:|recovery:|misplaced"
# Detailed PG states
ceph -s | grep -A15 "pgs:"
# Per-OSD utilization (track if overfull OSD is draining)
ceph osd df | grep "^ 7 "
# Estimated duration: misplaced_objects / objects_per_second
```
## Recovery Monitoring Cron Pattern
```
Schedule: every 30 minutes
Command: ssh to monitor node, run `ceph status`, report:
- PGs remapped/backfilling count
- % misplaced objects
- OSD 7 utilization
- Recovery speed
- Alert if any OSD down or health ERR
- Announce "COMPLETE" when 0 remapped PGs
```
## Pitfalls: Setting backfill_full_ratio (2026-07-12)
Three commands FAIL when trying to raise the backfill full ratio — only
ONE works:
```bash
# ✅ CORRECT — CLI command with hyphen (not underscore):
ceph osd set-backfillfull-ratio 0.97
# Verify: ceph osd dump | grep backfillfull_ratio → "backfillfull_ratio 0.97"
# ❌ WRONG — underscore variant:
ceph osd set-backfillfullratio 0.97
# → "no valid command found" (EINVAL)
# ❌ WRONG — MON config set:
ceph config set mon mon_osd_backfillfull_ratio 0.97
# → "mon_osd_backfillfull_ratio is special and cannot be stored by the mon"
# ❌ WRONG — injectargs on specific OSD:
ceph tell osd.10 injectargs "--osd_backfill_full_ratio 0.97"
# → "failed to parse arguments: --osd_backfill_full_ratio,0.97" (EINVAL)
# injectargs only accepts runtime-tunable OSD params, not full-ratio thresholds.
```
The ratio is a MON-level OSD map parameter, not a per-OSD config. It can
ONLY be changed via `ceph osd set-backfillfull-ratio` (CLI command, not
config set). Similarly: `ceph osd set-nearfull-ratio` and
`ceph osd set-full-ratio` for the other thresholds.
## Pitfalls: Pool-Level `backfillfull` Flag (2026-07-13)
When pools show the `backfillfull` flag in `ceph osd dump`, attempting
to unset it at the pool level FAILS:
```bash
# ❌ WRONG — no such pool flag:
ceph osd pool unset 6 backfillfull
# → "no valid command found; 1 closest matches: osd pool unset noautoscale"
# ❌ WRONG — all pool IDs tried, all fail:
for pool in 1 5 6 7 8 9 10; do ceph osd pool unset $pool backfillfull; done
# All return EINVAL
```
The `backfillfull` flag on a pool is a DERIVED condition — it appears when
any OSD in the pool's up/acting set is above the `backfillfull_ratio`.
It is NOT a settable pool flag. To clear it, fix the underlying OSD
condition: raise `backfillfull_ratio` or reweight the overfull OSD.
```bash
# ✅ CORRECT — raise the ratio (clears backfillfull on all pools):
ceph osd set-backfillfull-ratio 0.99
# ✅ ALSO — reweight the overfull OSD:
ceph osd reweight 7 0.8
```
## Pitfalls: `osd_recovery_max_active` Behavior (2026-07-13)
`ceph config set osd osd_recovery_max_active 3` accepts the value and
`ceph config get osd osd_recovery_max_active` returns 3. However,
`ceph tell osd.N config get osd_recovery_max_active` may return empty
string — the OSD interprets 0 or empty as "auto/default". Despite this,
setting it alongside `osd_max_backfills` appeared to help overall. Don't
rely on this parameter alone — use `osd_max_backfills` as the primary lever.
## Pitfalls: `full ratio(s) out of order` (2026-07-13)
When adjusting full/nearfull/backfillfull ratios, you MUST preserve the
ordering: `nearfull_ratio < backfillfull_ratio < full_ratio <= osd_failsafe_full_ratio`.
The `osd_failsafe_full_ratio` is hardcoded at **0.97** and cannot be changed.
If you set `full_ratio` above 0.97, the cluster goes to `HEALTH_ERR`:
```
[ERR] OSD_OUT_OF_ORDER_FULL: full ratio(s) out of order
osd_failsafe_full_ratio (0.97) < full_ratio (0.98), increased
```
**Safe ratio combinations for a cluster with an OSD at 95%:**
```bash
# ✅ CORRECT — all ratios below failsafe (0.97), properly ordered:
ceph osd set-nearfull-ratio 0.94
ceph osd set-backfillfull-ratio 0.96
ceph osd set-full-ratio 0.97 # == failsafe, OK
# ❌ WRONG — full_ratio above failsafe:
ceph osd set-full-ratio 0.98 # → HEALTH_ERR: out of order
```
**With an OSD at 95.2% utilization:**
- `nearfull_ratio` 0.94 → OSD at 95.2% shows `nearfull` (WARN, acceptable)
- `backfillfull_ratio` 0.96 → OSD at 95.2% is NOT backfillfull → backfill proceeds
- `full_ratio` 0.97 → OSD at 95.2% is NOT full → client I/O continues
If the OSD drains below 0.94, all flags clear automatically.
## Pitfalls: `ceph osd reweight` vs `ceph osd crush reweight` (2026-07-13)
Two DIFFERENT commands that both change OSD weighting:
```bash
# Runtime reweight — temporary, lost on OSD restart:
ceph osd reweight 7 0.8
# Changes the `reweight` column in `ceph osd df`. Persists until OSD restart
# or cluster-wide reweight-by-utilization. Does NOT change CRUSH weight.
# Good for emergency drain of an overfull OSD.
# CRUSH weight change — permanent, affects PG distribution:
ceph osd crush reweight osd.7 0.96
# Changes the CRUSH `weight` column. Survives restarts. Changes how many
# PGs the OSD gets assigned going forward.
# Use this to match weight to actual device size.
```
**Decision guide:**
- Emergency: OSD is 96%+ and blocking recovery → `ceph osd reweight` (fast, temporary)
- Permanent: OSD weight doesn't match device size → `ceph osd crush reweight` (slow, proper)
- After recovery: Reset `reweight` to 1.0, set `crush weight` to true device size
## Post-Recovery Cleanup
After all PGs return to active+clean:
```bash
# Restore default ratios
ceph osd set-backfillfull-ratio 0.95
ceph osd set-nearfull-ratio 0.93
# Restore default backfill speed
ceph config set osd osd_max_backfills 1
ceph tell osd.* injectargs "--osd_max_backfills 1"
# Restore OSD weight (if it was reduced)
ceph osd crush reweight osd.7 1.0 # or original weight
# Verify cluster health
ceph health
ceph -s
```