> Smart Home Zentrale auf Proxmox. Steuerung, Automatisierung und Benachrichtigungen.
## Infrastruktur
- **Host:** `10.0.30.10` (HAOS VM)
- **SSH:** `hassio@10.0.30.10` (PW: 1P Vault "Hermes")
- **URL:** `https://homeassistant.familie-schoen.com`
- **Container:** `homeassistant` (Docker)
## MQTT
- **Broker:** Mosquitto Add-on v7.1.1 auf localhost:1883
- **HA MQTT User:** ehemals `opendtu` (BROKEN — ACL blockiert), gefixt
- **ACL:** `/etc/mosquitto/acl` definiert `user homeassistant` + `user addons`
- **Auth Plugin:** `go-auth.so` (files,http backends)
## Automations
- **File:** `/config/automations.yaml` (35 Automations)
- **Schreibmethode:** SSH → `docker exec homeassistant chmod 666`, danach restore 644
- **Reload:** REST API mit JWT (HS256, signed from `/config/.storage/auth`)
### Frigate AI Notification v3 (ID 1714065780832)
- **Trigger:** MQTT `frigate/reviews` (severity=alert, Kameras Einfahrt/Terrasse) — NICHT `frigate/events` (Raw=Spam)
- **Gate:** llmvision.image_analyzer (noris gemma-4-31b-it) VOR Push, binär KRITISCH/NORMAL
- **Suppress:** sub_labels Sarah/Dominik; 300s Kamera-Cooldown; Review-ID-Dedup
- **Push:** GENAU EIN kombinierter (Titel+Verdict+Objekte+Bild) nur bei KRITISCH ∨ KI-Fail ∨ Person (24/7, v3.1)
- Siehe [[systems/frigate]] + Solution Doc `bug-fixes/2026-10-10-frigate-notification-spam-review-alerts.md`
## Notify Services
| Service | Status |
|---------|--------|
| `notify.mobile_app_iphone_dominik` | ✅ aktiv |
| `notify.mobile_app_sarahs_iphone_app` | verfügbar |
| `notify.mobile_app_ipad_2` | verfügbar |
| `notify.mobile_app_sm_x205` | verfügbar |
## Entitäten
- Kameras: `camera.einfahrt_2`, `camera.terrasse_2` (Suffix `_2` wegen verwaister Integration)
- Motion: `binary_sensor.einfahrt_motion_2`, `binary_sensor.terrasse_motion_2`
- Input Text: `input_text.frigate_last_event_id` (dedup storage, max 255 chars)
## Snapshots
- Gespeichert: `/config/www/snapshots/{camera}_latest.jpg`
- URL: `/local/snapshots/` (HTTP 200, keine Auth)
## JWT Auth
1. `jwt_key` aus `/config/.storage/auth` lesen
2. Client `Hermes_202606` (token id `1444b2c6757b4d66a6f8f8e5899b4e6a`)
3. HS256 signieren, Bearer Header
4. `?return_response=true` für Service-Call Responses
## Integrations
- Frigate (MQTT)
- LLM Vision (noris AI `gemma-4-31b-it`)
- Tibber (Strom)
- Marstek Speicher (VENUS-E, IP 10.0.50.113)
- NUT (APC Back-UPS ES 700G via ms-a2-1, `10.0.20.92:3493`, User monuser; Sensors `sensor.apc_*`; Entry `5e1d2138235140eb9b476e9d6779c228`; deployed via `iac-homelab/epic-9-ups-nut`)
- Various sensors (Xiaomi BLE, etc.)
## Xenia Kaffeemaschine (Stand 11.10.2026)
- ESP32 FW 3.9, IP 10.0.50.128 (VLAN 50, SSID IoT), REST `/api/v2/overview` (enthält MA_CUR_PWR in A!), `/api/v2/machine/data|status|control`
- **WARNUNG: MA_CUR_PWR ist AMPERE** — Power (W) = MA_CUR_PWR × Spannung L1 (`sensor.sn_3007105790_metering_voltage_l1` ≈ 234 V)
- Sensoren: `sensor.xenia_machine_data` (REST, scan_interval 1s, attr-basiert robust), `sensor.xenia_current_power_2` (GUI-Template, W), `sensor.xenia_total_energy_2` (Integration daraus), `sensor.xenia_status`, `switch.xenia_power` (Alexa-Pfad, rest_command control), Wrapper `sensor.xenia_active_power` (Disagg)
- **Fix 11.10.:** `xenia_current_power_2` war seit ~Aug tot (Entity-Rename `xenia_current_power`→`current_power_consumption` brach GUI-Template-String) → neu: `state_attr('sensor.xenia_machine_data','MA_CUR_PWR')|float(0) × voltage_l1|float(0)`; Metadaten (W/power/measurement) via Options-Flow komplett erhalten. Lesson: GUI-Template-Strings überleben Entity-Renames NICHT; REST-Sensoren feuern nur bei Wertänderung (idle = wenige History-Punkte ≠ offline); ESP32-Ping-Jitter (bis 550 ms) ist Power-Save, HTTP ist schnell (12–50 ms)
- **OFFEN (manuell, Setter defekt):** Web-UI http://10.0.50.128: `MA_MAX_AMPERE` 0→10, `MA_SET_TIMER_ECO_MA` 0→5 restaurieren (Fehlschrieb 05.10.)
- 4 Leichen im HA-Config-Dir: xenia_fix/modern/patch/remove_di.py (Alt-Sessions, ignorieren)
## EMHASS Batteriesteuerung
- **Endpoint:** `http://10.0.30.10:5000` (v0.18.4)
- **Architektur:** EMHASS = Sole Optimizer. Virtuelle 16 kWh Batterie (BYD 11k + Marstek 5k).
- **Config API:** `POST /set-config` überschreibt GESAMTE Konfig (kein Partial-Update!). Immer alle Felder senden. Siehe Solution Doc `integrations/2026-10-02-emhass-set-config-overwrite-pitfall.md`.
- **Akuelle Config (2026-10-02):**
- Capacity 16000Wh, Charge/Discharge 6700W, Efficiency 0.9
- Target SoC 0.15 (15%), Min SoC 0.1, Max SoC 1.0
- `set_battery_dynamic: True`, `set_use_battery: True`
- SoC sensor: `sensor.total_soc`, Power sensor: `sensor.batteries_power_out_total`
- **Kaskaden-Automation** (`1774430238377`, ON): EMHASS target → BYD (803 Auto default, 802 bei `target<=0 && pv<100`) + Marstek (Rest via `sensor.marstek_target_power`)
- **Template Sensoren:** `sensor.smart_battery_target` (EMHASS), `sensor.marstek_target_power` (Plan A: smart_target − actual_BYD_discharge). `sensor.sma_target_power` ENTFERNT (Double-Counting Bug).
- **Cutover (2026-10-09):** v2 (`emhass_optimizer_v2.py --publish --allow-grid-charge`) ist EINZIGER Produzent; Cron `a32005d62226` (runner `emhass-optimizer-v2-runner.sh`). v1 + Shadow-Collector `d046e808f543` + Watchdog `19aef2351273` pausiert = Rollback-Hebel. Race-Guard 30/20 s. Details: [[reference/emhass-cascade-automation-architecture]]
- **Publish-Pfadbruch 11.10. (GEFIXT ~20:30 UTC):** Nach HA-Core-Restart (Recorder-Incident) DEADLOCK: `p_batt_forecast`/`soc_batt_forecast`/`plan_*` sind set_state-Entities (überleben Restart NICHT), v2 liest sie hart → jeder Tick FATAL → nichts publizierte je wieder. Zweiter RC: `rest_command`-URLs `localhost:5000` — HA läuft im HOST-Netz, Addon in HassIO-Bridge; nach Restart connection-reset (10.0.30.10:5000 ging stets). Fix: beide URLs → `http://10.0.30.10:5000` (Backup `configuration.yaml.bak-20261011-restcmd`) + `rest_command/reload`. Heal-Pattern: `POST :5000/action/publish-data` direkt ans Addon. Verifikation: v2-Tick 20:32 komplett, plan_* 48 Slots, Kaskade folgt. ⚠️ Legacy-Automation „Trigger EMHASS" (*\/15): dayahead-call 400 (Payload ohne pv/load-Arrays) — funktional durch v2-Cron abgedeckt, disable/fix offen. Solution Doc `integrations/2026-10-11-emhass-publish-path-break-after-restart.md`
- **Historie:** Phase-2 Shadow (08.10., Dual-Solve, Deferrables als Phantom-Last entfernt, CSV 17 Spalten); Arbitrage-Flip produktiv (08.10. 22:20, `set_nocharge_from_grid` false).
- **Backup:** `.bak.20261001_175804` für configuration.yaml + automations.yaml
- **NFS-Backups (Fix 2026-10-07):** Supervisor-Mounts `Backup_NFS` (usage=backup) + `Medien_NFS` (usage=media) → **10.0.20.100:/pool01_n2_redundant/HomeAssistant** (vorher tote 10.0.30.100, verloren beim NAS-Crash-Reboot 03.10.). Volle automatische Backups ~03:27 UTC nightly. Monitoring: Hermes-Cron `2006a91fba21` (Alert bei Backup-Alter >30h). Lösungsdoku: `docs/solutions/bug-fixes/2026-10-07-ha-audit-nfs-mount-failure-after-nas-crash.md`
## PV-Anlage & Forecasts (Stand 11.10.2026)
**Arrays/WR:**
| Array | WR | Strings | kWp/Real | Forecast-Lage |
|---|---|---|---|---|
| Dach Teil 1 | SMA SB SN 3006252807 (10.0.50.201) | 2 (A+B, je String Ausrichtung unklar, SO/SW-Mix) | ~5,7 kWp; 6,7 kWh/11.10. | nur via FS-Site "Dach Südwest" (225°/23°/5760 W) — Zuordnung zu WR unbelegt |
| Dach Teil 2 | SMA SB SN 3006252817 (10.0.50.203) | 2 (dto.) | ~4,0 kWp; 6,7 kWh/11.10. | FS-Site "Dach Südost" (145°/24°/4000 W) — Zuordnung unbelegt |
| Speicher | SMA SBS SN 3007105790 (10.0.50.202, BYD) | keine PV-Strings | — | n/a |
| Zelt | Hoymiles HM-1500 (OpenDTU 10.0.40.55) | 2 Module zeltartig SW/NE aneinandergelehnt | 1,5 kWp; 2,1 kWh | ✅ FS-Sites "Zelt Südwest"+"Zelt Nordost" (65°/225°+65°/45°, je 750 W) seit 11.10. |
| Schuppen 1 | Hoymiles HMS (Limit 2250 W) | SW, ~5° flach | 2,2 kWp; 2,9 kWh | FS-Site ✓ (225°/5°/2200) |
| Schuppen 2 | Hoymiles HMS (Limit 2250 W) | SW, ~5° flach | 2,64 kWp; 3,5 kWh | FS-Site ✓ (225°/5°/2640) |
Aggregation: `sensor.pv_production` = min_max über 5 Sensoren (2×SMA grid_power + 3×Hoymiles) ✓ korrekt.
⚠️ `sensor.pv_daily_energy_total` = SUMME der 3 SMA daily_yields OHNE Hoymiles (−11%) und inkl. SBS-Batteriedurchsatz — nicht als PV-Tagesertrag verwenden!
**Forecast-Systeme (3 parallel):**
1. **Solcast** (Custom, Entry `01KKTKEN0VAWQTQCS4WWCQJWPT`) = PV-Input für EMHASS-v2-Optimizer (pooled aus `*_prognose_heute/morgen/tag_3` detailedHourly). Sites: "Schön Rohr" (043e-b831-88bf-b087, 16 kW, Azimut -132,6°/Tilt 19°, Freystadt = gemittelte Gesamtanlage) AKTIV; "Ogdak Netherlands" (59c8-caae-52f5-1686, Solcast-DEMO-Site Apeldoorn/NL) seit 11.10. **excludiert** (war ~9,6/23,4 kWh Phantom-PV!). API-Quota 30/Tag (Site-getrieben), hard_limit 100.
2. **forecast.solar** (Core, 4 Subentries): Dach SW/SO, Schuppen 1/2 — Dashboard-only, kein Optimizer-Input. Nutzer-Beschluss 11.10.: **komplett neu bauen** (war unbedacht eingerichtet). Achtung: API liefert lokale Timestamps; HA-Sensoren zeigten +2h-versetzte Werte (physikalisch unmögliche "Resttag"-Energie nach Sonnenuntergang) — beim Rebuild prüfen.
3. **EMHASS-Addon intern** (open-meteo + pvlib, generisches Fronius/CSUN-Modell) — irrelevant, v2-Optimizer published eigene Pläne.
**Bekannte Issues (11.10.):**
- ✅ TZ-Bug `emhass_optimizer_v2.py::build_pv_series` **GEFIXT 18:29** (`tzinfo=BERLIN` statt utc, Backup `.bak-20261011-tzfix`): Live-Tick 18:28 zeigte erstmals korrekte Abendkurve (36 W/18:30, 0 W nach Sunset statt ~1750 W Phantom).
- ✅ Reload-Race-Gefahr **GEHÄRTET 18:47**: `collect_solcast_pools()` mit 3×10s-Retry (Solcast-Options-Reload setzt Sensoren ~16s `unavailable`; 18:43-Tick crashte laut doctrine-konform).
- ✅ forecast.solar: **Zelt-Sites ergänzt** — "Zelt Südwest" (65°/225°/750 W) + "Zelt Nordost" (65°/45°/750 W), Area Photovoltaik. Dach/Schuppen-Entries validiert (SW/SE-Split ~62/38 ↔ 5,76/4,0 kWp passt zu Messdaten). HA-Parser ist KORREKT (Bibliothek fordert `time=utc` an; früherer +2h-Verdacht war Eigen-Parse-Artefakt).
- ✅ Solcast: `auto_dampen=True` + `get_actuals=True` + Kalibrierquelle `sensor.pv_production` (Validator-Kopplung "dampen_without_actuals" beachtet). Dämpfung lernt ab jetzt.
- ✅ `sensor.pv_daily_energy_total` repariert: Hoymiles REIN, SBS-Batteriedurchsatz RAUS (19,44→22,03 kWh, real ~22,4).
- 🟡 Solcast-Single-Site "Schön Rohr" = Mittelung (1 Azimut/Tilt für 6 Arrays) — Struktur grob, aber jetzt kalibrierend gedämpft; Feintuning über auto_dampen-Daten (Tage) beobachten.
- ✅ **Sauna-Shelly misst NETTO** (HM-1500 speist auf dem Sauna-Stromkreis rück): Shelly = Kreislast − Zelt-PV (validiert 11.10.: Steigung −0.983, r=−0.9985; Integrale 2,07 vs. 2,13 kWh). Template `Sauna Active Power` GEFIXT 19:39: `max(0, ΣPhasen + hm_1500_power)` mit float(0)-Guards — liefert jederzeit die wahre Sauna-Last, "Rest"-Helfer korrekt.
- Solution Doc: `docs/solutions/integrations/2026-10-11-solcast-sample-site-contamination-and-tz-shift.md`
## Garagentor (free@home ch0003) — Flanken-Toggle-Semantik
- **Kanal:** `switch.garagentor` = free@home Schaltaktor `ABB20C351F51/ch0003`, treppenlicht-parametriert (Kanal nach Aktivierung AN bis Timer-Ablauf). `cover.garagentor` = Template-Cover darüber (open/close = je EINE Kanalaktivierung).
- **Motor toggelt auf JEDE Kanalflanke.** Einzelimpuls = sauber Umschalten (belegt: 17:51 Puls → schloss in ~90s). **Zwei schnelle Flanken = Start-Stopp** (belegt: 17:07 mein OFF→ON-Doppelpuls, 17:48 Nutzer-Doppelklick — jeweils blieb das Tor offen!). Doppelklick-Gewohnheit wirkt der Schließfahrt aktiv entgegen.
- **BUG (seit 05.10.):** `switch.garagentor` = `unknown`, 0 Logbook-Events — Statusrückmeldung SysAP→HA für ch0003 tot. SysAP-REST braucht Credentials (401 anon + admin/admin), SSH-Addon gestoppt → Diagnose dort blockiert.
- **Automations (2026-10-10, REST-config):** `warn_offen_beim_verlassen` (Person weg >2min + Garagentor/Esszimmertür offen → time-sensitive Push mit CLOSE_GARAGE-Button) + `garagentor_push_close` **v8 Single-Edge** (Guards: offen+90s stabil+45s Anti-Doppeltipp; EIN switch.turn_on, KEIN turn_off-Präludium; 45s-Verifikation per Neigungssensor; Retry erst nach 480s; ehrliche Fehler-Push). Tag `warn_offen_beim_verlassen` aktualisiert Notifications.
- Nur 2 physische Öffnungssensoren im Haus: Garagentor (Neigungssensor+Cover) + Esszimmertür (`binary_sensor.esszimertur_contact`, Aqara). free@home-Panels sind Taster, KEINE Fensterkontakte.
- Solution Doc: `docs/solutions/integrations/2026-10-10-freeathome-garage-impulse-toggle-semantics.md`
## Related
- [[systems/frigate]] — NVR Integration
- [[systems/noris-ai]] — LLM Vision Provider
- [[reference/ip-map]] — IP Assignments
- [[reference/emhass-cascade-automation-architecture]] — Kaskaden-Architektur Details